Thc removal from hemp oil

Chromatography Forum: LC Archives: Thc removal from hemp oil
Top of pagePrevious messageNext messageBottom of pageLink to this message  By Meg Raj on Thursday, June 6, 2002 - 07:15 am:

New regulations in US require all hemp products to be free of THC. Any ideas for removing this from an ethanol extract of hemp? Meg Raj


Top of pagePrevious messageNext messageBottom of pageLink to this message  By mkane on Friday, June 7, 2002 - 01:42 am:

IN SPE a mixture of Hexane /ethyl acetate and acetone 50:40:10 is used to elute THC from a silica surface. For any would be "pot heads" this would be quite toxic!


Top of pagePrevious messageNext messageBottom of pageLink to this message  By Meg Raj on Tuesday, June 18, 2002 - 12:01 am:

thanks for the quick response mkane. Some of my hemp products are for food and tonics so need to remove the THC without leaving toxic residues.